O₂-Pressure regulator (DMX)

[Translate to Englisch:] Sauerstoff-Druckminderer
[Translate to Englisch:] Technische Zeichnung
  • Extremely high flow rate, compact design
  • Burn-out proof by control without diaphragm
  • With 2 manometers for indication of input pressure (max. 40 bar) and of working pressure (3 - 16 bar)
  • Reduction of the input pressure to approx. 3 - 16 bar, working pressure can be adjusted as wanted
  • Adjustable even under pressure
  • Compensates pressure fluctuations
for lance pipe Ø Input pressureOutput pressureCapacityConnection (DIN EN 560)
[bar][bar][Nm³/h]A1A2
1/2" - 3/4“
403 - 162000G 1G 1
3/4" - 1"403 - 162000G 1 1/4G 1 1/4
1" - 1 1/4"403 - 162000G 1 1/2G 1 1/2

 

 

You can see the standard versions available from stock. We also develop special designs according to your special requirements.